5-channel Electrotherapy / Ultrasound Combo

EU-941 has 5 independent channels and multi-frequency treatment probes.

ITO WEBSITE

3-Channel Combination Therapy

Model EU-921 and SU-520BK


5-Channel Combination Therapy

Model EU-941 and SU-540



     Low BNR

BNR is one of the indications for quality of the ultrasound beam.   The BNR of EU-941 is 2.4 to 4.6 (IEC standards), a significantly low ratio.   Low beam non-uniformity ratio prevents hot spots and tissue damages.                 

47 Effective clinical programs for over 30 types of pathologies

 You can simply choose the area to be treated from Human body diagram.   All the pre-programmed parameters can be modified to suit your particular needs. 

13 Types of Frequently Used Current Modes Installed

AC: IF-4, IF-2, EMS, Russian, TENS, High Voltage (HV), Microcurrent (MCR), DC, Galvanic, Faradic, Diadynamic, Traebert (Ultras Reiz)
Diagnostic: I/T curve and AQ                 

Visual Probe Contact Status

 Clear light indications on both ultrasound probe and main unit to visually check whether the ultrasound energy is safely and effectively conducted into human body. 

EU-941  FEATURES

  • 5 Independent channels (4 for electrotherapy, 1 for ultrasound)
  • Large 7-inch TFT color touch screen
  • 47 Clinical programs with Human Body Diagram for 30 types of pathologies
  • A striking piano black finish
  •  210 memorable program numbers
  • User-defined protocol memories - 120
  • CURRENT AMPLITUDE (MAX):  IF-4 / IF-2 / EMS / Russian / TENS (100mA) , HV (600mA), MCR (750 uA), Glavanic (20mA), Faradic / Traebert / IT Curve / AQ (70mA)
  • FREQUENCY: IF-4 (1-250Hz), IF-2 (1-250Hz), EMS (20-250Hz), Russian (2.5kHz), HV (0.5-200Hz), TENS (0.5-250 Hz), MCR (0.2-400Hz), Galvanic (0.95-15.8Hz), Faradic (20-250Hz), Diadynamic (50 or 100 Hz), Traebert (142Hz), I/T Curve (0.33-0.5Hz) AQ (0.33Hz)
  •  

SU-540  FEATURES

  • Ultrasound Mode: Continuous, Pulsed (5%, 10%, 20%, 30%, 40%, 50%)
  • Ultrasound Intensity (max): Continuous - 2W/cm square, Pulsed - 3W/cm square
  • Ultrasound Frequencies: 1 MHz, 3 MHz
  • Pulse Frequency: 16 Hz, 48 Hz, 100 Hz
  • Timer: 30 mins
  • User-defined protocol memories - 120
  • Probe head diameter: Large (37.5mm) / Small (16mm)
  • BNR US Probe (IEC Standards): Large (4.6 for 1 Mhz / 2.4 for 3 Mhz) / Small (2.9 for 1 Mhz / 2.4 for 3 Mhz)
  • ERA US Probe (IEC Standards): Large (5.0 cm square for 1 Mhz / 5.0 cm square for 3 Mhz) / Small (0.7 cm square for 1 Mhz / 0.5 cm square for 3 Mhz)
  •  Dimensions: 350 (W) x 270 (D) x 145 (H)mm

Multi-channel Electrotherapy Unit

 ES-5200 has 28 Effective Clinical programs and 7'inch TFT Color Touch Screen for high visibility and functionality.

ITO WEBSITE

4 - Channel Electrotherapy Combo

Model ES-5400 and SU-540


2-Channel Electrotherapy Combo

Model ES-5200 and SU-520BK



  28 Effective Clinical 

  Programs for over 20

  types of pathologies

You can simply choose the are to be treated from Human Body Diagram.  By using these parameters, you can quickly accumulate know-how of treatment of various pathologies.   All the pre-programmed parameters can be modified to suit your particular nees.           

Sequential Mode

This mode allows you to apply two designed therapeutic courses continuously without having to modity unit parameters.

 

ES-5200 FEATURES

  • LCD touch screen color display: TFT 7’ / 85.9 (H) x 154 (W) mm
  • 13 types of frequently used current modes installed
  • Constant current / constant voltage modes
  • FREQUENCY: IF-4 (1-250Hz), IF-2 (1-250Hz), EMS (20-250Hz), Russian (2.5kHz), HV (0.5-200Hz), TENS (0.5-250 Hz), MCR (0.2-400Hz), Galvanic (0.95-15.8Hz), Faradic (20-250Hz), Diadynamic (50 or 100 Hz), Traebert (142Hz), I/T Curve (0.33-0.5Hz) AQ (0.33Hz)
  • CURRENT AMPLITUDE (MAX):  IF-4 / IF-2 / EMS / Russian / TENS (100mA) , HV (600mA), MCR (750 uA), Glavanic (20mA), Faradic / Traebert / IT Curve / AQ (70mA)
  • 13 current modes : IF-4, IF-2, EMS, Russian, TENS, Hi-Voltage, MCR, Galvanic, Faradic, Diadynamic, Traebert, I/T Curve, AQ
  • IF carrier frequency: 2,4,5,8,10 kHz
  • Vector sweep (for IF-4): 0, 15, 30, 45 degrees
  •  User-defined protocol memories - 120
  • Dimensions: 345 (W) x 270 (D) x 145 (H)mm

Ultrasound Therapy

US-751 features large 7" TFT Color Touch Screen for high visibility and functionality.   Attractive features include low BNR and conveniently connect both small (2cm) and large (11cm) head ultrasound probes.

ITO WEBSITE


  

   7-Inch TFT Color

   Touch Screen

The large color touch screen dramatically improves visibility and functionality.  The screen is 20% larger than the screen used in previous models.    

Low BNR

BNR is one of the indications for quality of the ultrasound beam.   The BNR of US-751 is 2.4 to 3.0.  (IEC Standards), a significantly low ratio.   Low beam non-uniformity ratio prevents hot spots and tissue damages.

Human Body Diagram

You can simply choose the area to be treated from Human Body Diagram.   42 parameters are pre-set.   All the pre-set parameters can be modified to suit your particular needs.               

Visual Probe Contact Status

 Clear light indications on both ultrasound probe and main unit to visually check whether the ultrasound energy is safely and effectively conducted into human body. 

Selectable Coupling Sensitivity

You can select the appropriate coupling sensitivity between ultrasound gel and medicated gel.                 

2 Ultrasound Probes Connectable

You can connect both small (2cm2) and large (11cm 2) head ultrasound probes to quickly change the treatment head.

US-751  FEATURES

  • A user-friendly ultrasound therapy system with a convention-defying style and color scheme
  • A striking piano piano finish
  • A choice of two melodies to signal end of therapy
  • Ultrasound Mode: Continuous, Pulsed (5%, 10%, 20%, 30%, 40%, 50%)
  •  Intensity (max): 3 W/cm square pulsed or 2W/cm continuous
  • Pulse Frequency: 16 Hz, 48 Hz, 100 Hz
  • Ultrasound frequencies: 1 MHz, 3 MHz
  •   Probe Head Diameter: 2
  • BNR US Probe (IEC Standards): Large (3.0 cm square for 1 Mhz / 2.4 cm square for 3 Mhz) / Small (2.9 cm square for 1 Mhz / 2.4 cm square for 3 Mhz)
  • ERA US Probe (IEC Standards): Large (5.0 cm square for 1 Mhz / 5.0 cm square for 3 Mhz) / Small (0.7 cm square for 1 Mhz / 0.5 cm square for 3 Mhz)
  • Timer: 1 - 30 mins, counts only actual therapy time
  • Dimensions: 290 (W) x 233 (D) x 96 (H) mm

Portable Ultrasound Therapy

Model US-101L / US-103S


     Portability

As the weight of these units is less than 200 g and the unit size is very compact, you can easily bring them anywhere you like.             

Low BNR

BNR is one of the indications for quality of the ultrasound beam.   The BNR of US-101L / 103S is 2.4 to 3.5.  (IEC Standards), a significantly low ratio.   Low beam non-uniformity ratio prevents hot spots and tissue damages. 

US-101L  FEATURES

  • One-hand operation
  • Waterproof design
  • Rechargeable Battery available (optional)
  • 5 pre-set parameters installed (modifiable)
  • 1.44" color LCD
  • Ultrasound frequency: 1.0 MHz
  • Pulse frequency: 100 Hz
  • Intensity (max): 3 W/cm square pulsed or 2W/cm continuous
  • US mode: continuous, pulsed (duty 5,10, 20,30,40,50)
  • Timer: 30 min +/- 1 min
  • Dimensions: 134 (H) x 55 (D) x 59 (W) mm 

Traction Therapy

TM-400 has 8 traction modes.   It is user-friendly as the parameter of each mode can be modified to suit your particular needs 

ITO WEBSITE

Traction Therapy

Model TM-400

Height Adjustable Traction Table (UK) 

Model TM-400 + 502TE

Fixed Height Traction Table (Japan)

Model TM-4001F

Height Adjustable Traction Table

(Japan)

Model TM-4001E


     

    8 Traction Modes

Most common effective 8 traction modes are installed.   Parameter of each mode can be modified to suit your particular needs.           

30 Memorable Program Numbers

 You can save 30 treatment parameters and quickly load & modify them as you like.   This function facilitates treating numerous patients. 

Automatic Calibration for Traction force

Innovative automatic calibration function for traction force is installed.  It contributes to maintaining accurate and suitable traction force.               

Selectable Pulling Speed

 You can select pulling speed from 1:1, 1:2, 1:4, 1:6 and 1:8.

TM-400  FEATURES

  • Automatic calibration of traction force to maintain correct traction force (PAT.P)
  • Large and high visibility LCD screen - 116 (W) x 87 (H) mm
  • Exclusive traction table available (optional)
  • Set and actual values of traction force are displayed
  • Patient switch for safe treatment
  • 8 Traction Modes: Intermittent, Static, Progressive-intermittent, Progressive-static, Progressive-regressive, Cyclic-intermittent, Cyclic-static, Cyclic
  • Force range: 1 - 90 KG / (1 - 198 LBS) 
  • User-defined protocol memories: 30
  • Timer: 1 - 99 minutes
  • Dimension: 260 (W) x 350 (D) x 295 (H) mm
  •  

Radio Frequency Therapy

DIA-TKR 800 is state-of-the art Tecar Therapy.   With AV mode, tecar therapy will never be the same: with 3 new modes designed to meet the needs of the therapist, DIA-TKR 800 transforms into a single platform which is able to best support therapeutic activity.

ITO WEBSITE


     Single handpiece

DIA-TKR 800 features a single handpiece for both capacitive and resistive modes.  With one simple command, it is possible to change from one mode to the other: simplicity and functionality in cutting-edge therapeutic technology.           

The new Tecar-Therapy: AV Mode

The AV Mode allows integration of 2 new modes: Automatic Mode and Automatic Pulsed Mode.   With AV mode, tecar therapy will never be the same: with 3 new modes designed to meet the needs of therapists. 

DIA-TKR 800  FEATURES

  • Capacitive and Resistive Application
  • Adjustable Pulse Mode
  • Power: 120 W effective (350 Wpp)
  • Biotransfer: Display and acoustic signal
  • Connection: Contact control system
  • Cable check: Automatic check with graphic and acoustic feedback
  • Display: Color TFT 5.7” Touch-screen
  • Absorption: 160 VA
  • Modes: Manual, Timed, Administration
  • Special mode: Timer, Adjustable Pulsed, Joule
  • Additional mode: Automatic, Automatic pulse
  • Dimensions: 320 (W) x 245 (D) x 130 (H) mm
  •  

High Power Laser Therapy

LAZR-215 

ITO WEBSITE


     Interaction

     between power

     and depth

The ability of the laser to penetrate to the depth is often incorrectly attributed to only the wavelength.   In reality, the power has a fundamental role in the therapeutic action of laser on tissues.  Greater power transmits more energy, overcoming the natural dispersion of the laser and reaching the seat of the injury.              

Characteristics of Wavelengths

The 810 nm wavelength allows rapid activation of the process of hemoglobin oxygenation: transferring the correct energetic supply to muscles and tendons, facilitating regeneration.   

The 980nm wavelength optimizes the action on thermo and mechanical receptors.   When associated with the E2C mode it ensures correct interaction with peripheral nervous system, activating the Gate Control mechanism for a rapid analgesic effect. 


     Innovative "E2C"

     Emission Mode

This patented emission type generates variable power of laser impulses.   "Comfort Heat Emission" combined with thermo-mechanical action on perpheral receptors allow rapid polarization of nocicpetors, polarizing A-delta fibers and blocking pain signals throught the Gate Control process.   The analgesic action leads to a significant reduction in pain from the first treatment, with no side effects.         


     

                 

LAZR-215 FEATURES

  • Effective 7 emission modes (Pulsed, Single Pulse, Continous Wave, Custom, AntInf, Burst and E2C) 
  • Clinical protocols for over 60 pathologies
  • Specific protocols for 5 main effects
  • Full color, 5.7" LCD touch screen
  • Guide Light: 650 n m (wavelength) / 3mW (power)
  • Laser power up to 7 W
  • Operation Mode: Joule, Timer, Trigger Point
  •